On-line temperature measurement in a plasma reactor for fullerene synthesis - Mines Paris Accéder directement au contenu
Communication Dans Un Congrès Année : 2003

On-line temperature measurement in a plasma reactor for fullerene synthesis

Résumé

Vaporization of carbon particles injected in a plasma flow is an alternative to existing processes for mass production of fullerenes. In order to obtain a large fullerene-soot production the residence time of particle at temperature larger than the vaporization temperature must be large enough. This critical point was checked in the pilot reactor by OES. The helium plasma was generated inside a carbon nozzle by a 3-phase AC plasma source using graphite electrodes. The plasma flow was then cooled in a graphite cylinder. Plasma temperature was measured using Hβ line and C2 Swan band in the upper part of the nozzle and at the entrance of the cylinder respectively. The results show that inside this volume, the plasma temperature is larger than or equal to 4500K and is very sensitive to the arc current.
Fichier non déposé

Dates et versions

hal-00529785 , version 1 (26-10-2010)

Identifiants

  • HAL Id : hal-00529785 , version 1

Citer

Stéphane Abanades, J.M. Badie, Gilles Flamant, Laurent Fulcheri, José Gonzalez-Aguilar, et al.. On-line temperature measurement in a plasma reactor for fullerene synthesis. 7th international Thermal Plasma Processes conference (TPP7), Jun 2002, Strasbourg, France. p. 47-53 - ISBN 1-56700-192-0. ⟨hal-00529785⟩
204 Consultations
0 Téléchargements

Partager

Gmail Facebook X LinkedIn More