A. Fujitaka, Application of Low Global Warming Potential Refrigerants for Room Air Conditioners, 2010 International Symposium on Next Generation air Conditioning and Refrigerant Technology, pp.17-19, 2010.

H. Hara, M. Oono, and I. Iwata, Experimental Study of Low GWP Refrigerants for Room Air Conditioners, 2010 International Symposium on Next Generation air Conditioning and Refrigerant Technology, pp.17-19, 2010.

X. N. Han, Cycle performance study on R32/R125/R161 as an alternative refrigerant to R407C, Applied Thermal Engineering, vol.27, issue.14-15, pp.2559-2565, 2007.
DOI : 10.1016/j.applthermaleng.2007.01.034

S. Kondo, A. Takahaski, K. Tokuhashi, and A. Sekiya, RF number as a new index for assessing combustion hazard of flammable gases, Journal of Hazardous Materials, vol.93, issue.3, pp.93-259, 2002.
DOI : 10.1016/S0304-3894(02)00117-6

K. Park and D. Jung, Thermodynamic performance of HCFC-22 alternative refrigerants for residential air-conditioning applications, Energy and Buildings, vol.3, pp.675-680, 2006.

C. Rahal and D. Clodic, Method of choice of low TEWI refrigerant blends, International Refrigeration and Air Conditioning Conference at Purdue University, 1920.

J. Stene, Residential CO2 heat pump system for combined space heating and hot water heating, International Journal of Refrigeration, vol.28, issue.8, pp.1259-1265, 2005.
DOI : 10.1016/j.ijrefrig.2005.07.006

K. Takizawa, Burning velocity measurement of fluorinated compounds by the spherical-vessel method, Combustion and Flame, vol.141, issue.3, pp.298-307, 2005.
DOI : 10.1016/j.combustflame.2005.01.009

Y. Zhao, L. Bin, and Z. Haibo, Experimental study of the inert effect of R134a and R227ea on explosion limits of the flammable refrigerants, Experimental Thermal and Fluid Science, vol.28, issue.6, pp.557-563, 2004.
DOI : 10.1016/j.expthermflusci.2003.06.005