Signal injection and averaging for position estimation of Permanent-Magnet Synchronous Motors - Mines Paris Accéder directement au contenu
Communication Dans Un Congrès Année : 2012

Signal injection and averaging for position estimation of Permanent-Magnet Synchronous Motors

Al Kassem Jebai
  • Fonction : Auteur
  • PersonId : 763686
  • IdRef : 168994011
François Malrait
  • Fonction : Auteur
  • PersonId : 936872
Philippe Martin
Pierre Rouchon

Résumé

Sensorless control of Permanent-Magnet Synchronous Motors at low velocity remains a challenging task. A now well-established method consists in injecting a high-frequency signal and use the rotor saliency, both geometric and magnetic-saturation induced. This paper proposes a clear and original analysis based on second-order averaging of how to recover the position information from signal injection; this analysis blends well with a general model of magnetic saturation. It also experimentally demonstrates the relevance for position estimation of a simple parametric saturation model recently introduced by the authors.
Fichier non déposé

Dates et versions

hal-00787794 , version 1 (12-02-2013)

Identifiants

  • HAL Id : hal-00787794 , version 1

Citer

Al Kassem Jebai, François Malrait, Philippe Martin, Pierre Rouchon. Signal injection and averaging for position estimation of Permanent-Magnet Synchronous Motors. Conference on Decision and Control (2012), Dec 2012, United States. pp.7608-7613. ⟨hal-00787794⟩