Vapor Liquid Equilibrium Data for the Furan-Toluene Binary System between 313.02 and 352.99 K - Mines Paris Accéder directement au contenu
Article Dans Une Revue Journal of Chemical and Engineering Data Année : 2017

Vapor Liquid Equilibrium Data for the Furan-Toluene Binary System between 313.02 and 352.99 K

Résumé

The study presents p-T-x-y phase equilibria measurements of an oxygenated compound (furan) and one of its potential solvent of extraction (toluene). The experimental technique of the equipment recently developed is based on a " static analytic " method. Measurements were done at three temperatures (313.02, 333.02 and 352.99 K) and pressures from 13 up to 375 kPa. The experimental data measured were successfully correlated, using a " gamma phi " approach, with the NRTL activity coefficient model.
Fichier principal
Vignette du fichier
Furan toluene manuscript February 2017.pdf (660.64 Ko) Télécharger le fichier
Origine : Fichiers produits par l'(les) auteur(s)
Loading...

Dates et versions

hal-01531268 , version 1 (01-06-2017)

Identifiants

Citer

Pascal Théveneau, Alain Valtz, Christophe Coquelet. Vapor Liquid Equilibrium Data for the Furan-Toluene Binary System between 313.02 and 352.99 K. Journal of Chemical and Engineering Data, 2017, 62, pp.1168-1172. ⟨10.1021/acs.jced.6b00424⟩. ⟨hal-01531268⟩